<?xml version="1.0" encoding="UTF-8" ?>
< oai_dc:dc schemaLocation =" http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd " >
< dc:title lang =" en-US " > Comparative analysis of the shoulder’s funcionality in patients undergoing proximal humerus osteosynthesis with fixed angle plate and locking screws </ dc:title >
< dc:title lang =" pt-BR " > Análise comparativa da funcionalidade do ombro em pacientes submetidos à osteossíntese do úmero proximal com placa bloqueada de ângulo fixo </ dc:title >
< dc:creator > Silva, Marina </ dc:creator >
< dc:subject lang =" en-US " > Humeral Fractures </ dc:subject >
< dc:subject lang =" en-US " > Shoulder Fractures/classification </ dc:subject >
< dc:subject lang =" en-US " > Shoulder </ dc:subject >
< dc:subject lang =" en-US " > Scales/UCLA </ dc:subject >
< dc:subject lang =" pt-BR " > Fraturas do Úmero </ dc:subject >
< dc:subject lang =" pt-BR " > Fraturas do Ombro/classificação </ dc:subject >
< dc:subject lang =" pt-BR " > Ombro </ dc:subject >
< dc:subject lang =" pt-BR " > Escalas/UCLA </ dc:subject >
< dc:description lang =" en-US " > Objective: To compare the scales of UCLA-modified Constant-Murley and the functional assessment of the shoulder patient undergoing osteosynthesis of the proximal humerus with fixed angle plate (PHILOS). Method: From September 2007 to June 2011 were selected HNMD in 10 patients treated, 20% were male with a mean age of 42.5 years and 80% female with a mean age of 60.5 years. The postoperative mean follow-up was 9 month and based on Neer classification, two patients had a fracture in three parts, 8 in 2 parts and no fracture in four parts. The functional assessment of the shoulder of patients compared using the scales UCLA and Constant-Murley. Results: The average overall score of UCLA was 23.5 points (8-35) and Constant-Murley score 50.7 points or classified as medium (bad - excellent). All fractures showed union, three patients after one year postoperative had the material synthesis removed by presenting subacromial impingement. Conclusion: It observed that the scale Constant-Murley is most suitable for evaluating the functionality of the shoulder in patients undergoing osteosynthesis of the proximal humerus, as assessed pain and range of motion more efficient and reliable. </ dc:description >
< dc:description lang =" pt-BR " > Objetivo: Comparar as escalas de UCLA (Universidade da California- Los Angeles) - modificada e Constant-Murley, na avaliação funcional do ombro de pacientes submetidos à osteossíntese do úmero proximal com placa de angulo fixo (PHILOS). Métodos: No período entre setembro de 2007 a junho de 2011 foram selecionados 10 pacientes tratados no Hospital Naval Marcílio Dias (HNMD), sendo 20% do sexo masculino com a média de idade de 42,5 anos e 80% do sexo feminino com média de idade 60,5 anos. O acompanhamento pós operatório dos pacientes foi em 9 meses e baseado na classificação de Neer, 2 pacientes apresentaram fraturas em 3 partes, 8 em 2 partes e nenhuma fratura em 4 partes. A avaliação funcional do ombro dos pacientes foi comparada usando as escalas mencionadas. Resultados: A média de escore global de UCLA foi de 23,5 pontos (8-35) e o escore de Constant-Murley 50,7 pontos sendo classificado como médio (ruim-excelente). Todas as fraturas apresentaram consolidação, 3 pacientes após um ano de pós operatório foram submetidos a retirada do material de síntese por apresentarem impacto subacromial. Conclusão: Foi observado que a escala de Constant-Murley é mais adequada para a avaliação da funcionalidade do ombro nos pacientes submetidos à osteossíntese do úmero proximal, uma vez que avaliou dor e arco de movimento de forma mais eficiente e fidedigna. </ dc:description >
< dc:publisher lang =" pt-BR " > Diretoria de Saúde da Marinha </ dc:publisher >
< dc:date > 2014-11-02 </ dc:date >
< dc:type > info:eu-repo/semantics/article </ dc:type >
< dc:type > info:eu-repo/semantics/publishedVersion </ dc:type >
< dc:format > application/pdf </ dc:format >
< dc:identifier > https://www.portaldeperiodicos.marinha.mil.br/index.php/abmn/article/view/684 </ dc:identifier >
< dc:source lang =" en-US " > Revista Arquivos Brasileiros de Medicina Naval; Vol 75 No 1 (2014): Arquivos Brasileiros de Medicina Naval; 10 </ dc:source >
< dc:source lang =" pt-BR " > Revista Arquivos Brasileiros de Medicina Naval; v. 75 n. 1 (2014): Arquivos Brasileiros de Medicina Naval; 10 </ dc:source >
< dc:source > 0365-074X </ dc:source >
< dc:language > por </ dc:language >
< dc:relation > https://www.portaldeperiodicos.marinha.mil.br/index.php/abmn/article/view/684/676 </ dc:relation >
</ oai_dc:dc >
<?xml version="1.0" encoding="UTF-8" ?>
< record schemaLocation =" http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd " >
< leader > nmb a2200000Iu 4500 </ leader >
< controlfield tag =" 008 " > "141102 2014 eng " </ controlfield >
< datafield ind1 =" # " ind2 =" # " tag =" 022 " >
< subfield code =" $a " > 0365-074X </ subfield >
</ datafield >
< datafield ind1 =" " ind2 =" " tag =" 042 " >
< subfield code =" a " > dc </ subfield >
</ datafield >
< datafield ind1 =" 0 " ind2 =" 0 " tag =" 245 " >
< subfield code =" a " > Análise comparativa da funcionalidade do ombro em pacientes submetidos à osteossíntese do úmero proximal com placa bloqueada de ângulo fixo </ subfield >
</ datafield >
< datafield ind1 =" 1 " ind2 =" " tag =" 100 " >
< subfield code =" a " > Silva, Marina </ subfield >
</ datafield >
< datafield ind1 =" " ind2 =" " tag =" 520 " >
< subfield code =" a " > Objetivo: Comparar as escalas de UCLA (Universidade da California- Los Angeles) - modificada e Constant-Murley, na avaliação funcional do ombro de pacientes submetidos à osteossíntese do úmero proximal com placa de angulo fixo (PHILOS). Métodos: No período entre setembro de 2007 a junho de 2011 foram selecionados 10 pacientes tratados no Hospital Naval Marcílio Dias (HNMD), sendo 20% do sexo masculino com a média de idade de 42,5 anos e 80% do sexo feminino com média de idade 60,5 anos. O acompanhamento pós operatório dos pacientes foi em 9 meses e baseado na classificação de Neer, 2 pacientes apresentaram fraturas em 3 partes, 8 em 2 partes e nenhuma fratura em 4 partes. A avaliação funcional do ombro dos pacientes foi comparada usando as escalas mencionadas. Resultados: A média de escore global de UCLA foi de 23,5 pontos (8-35) e o escore de Constant-Murley 50,7 pontos sendo classificado como médio (ruim-excelente). Todas as fraturas apresentaram consolidação, 3 pacientes após um ano de pós operatório foram submetidos a retirada do material de síntese por apresentarem impacto subacromial. Conclusão: Foi observado que a escala de Constant-Murley é mais adequada para a avaliação da funcionalidade do ombro nos pacientes submetidos à osteossíntese do úmero proximal, uma vez que avaliou dor e arco de movimento de forma mais eficiente e fidedigna. </ subfield >
</ datafield >
< datafield ind1 =" " ind2 =" " tag =" 260 " >
< subfield code =" b " > Diretoria de Saúde da Marinha </ subfield >
</ datafield >
< dataField ind1 =" " ind2 =" " tag =" 260 " >
< subfield code =" c " > 2014-07-03 00:00:00 </ subfield >
</ dataField >
< datafield ind1 =" " ind2 =" " tag =" 856 " >
< subfield code =" q " > application/pdf </ subfield >
</ datafield >
< datafield ind1 =" 4 " ind2 =" 0 " tag =" 856 " >
< subfield code =" u " > https://www.portaldeperiodicos.marinha.mil.br/index.php/abmn/article/view/684 </ subfield >
</ datafield >
< datafield ind1 =" 0 " ind2 =" " tag =" 786 " >
< subfield code =" n " > Revista Arquivos Brasileiros de Medicina Naval; v. 75 n. 1 (2014): Arquivos Brasileiros de Medicina Naval </ subfield >
</ datafield >
< datafield ind1 =" " ind2 =" " tag =" 546 " >
< subfield code =" a " > por </ subfield >
</ datafield >
< datafield ind1 =" " ind2 =" " tag =" 540 " >
< subfield code =" a " > ##submission.copyrightStatement## </ subfield >
</ datafield >
</ record >
<?xml version="1.0" encoding="UTF-8" ?>
< oai_marc catForm =" u " encLvl =" 3 " level =" m " status =" c " type =" a " schemaLocation =" http://www.openarchives.org/OAI/1.1/oai_marc http://www.openarchives.org/OAI/1.1/oai_marc.xsd " >
< fixfield id =" 008 " > "141102 2014 eng " </ fixfield >
< varfield i1 =" # " i2 =" # " id =" 022 " >
< subfield label =" $a " > 0365-074X </ subfield >
</ varfield >
< varfield i1 =" " i2 =" " id =" 042 " >
< subfield label =" a " > dc </ subfield >
</ varfield >
< varfield i1 =" 0 " i2 =" 0 " id =" 245 " >
< subfield label =" a " > Análise comparativa da funcionalidade do ombro em pacientes submetidos à osteossíntese do úmero proximal com placa bloqueada de ângulo fixo </ subfield >
</ varfield >
< varfield i1 =" 1 " i2 =" " id =" 100 " >
< subfield label =" a " > Silva, Marina </ subfield >
</ varfield >
< varfield i1 =" " i2 =" " id =" 520 " >
< subfield label =" a " > Objetivo: Comparar as escalas de UCLA (Universidade da California- Los Angeles) - modificada e Constant-Murley, na avaliação funcional do ombro de pacientes submetidos à osteossíntese do úmero proximal com placa de angulo fixo (PHILOS). Métodos: No período entre setembro de 2007 a junho de 2011 foram selecionados 10 pacientes tratados no Hospital Naval Marcílio Dias (HNMD), sendo 20% do sexo masculino com a média de idade de 42,5 anos e 80% do sexo feminino com média de idade 60,5 anos. O acompanhamento pós operatório dos pacientes foi em 9 meses e baseado na classificação de Neer, 2 pacientes apresentaram fraturas em 3 partes, 8 em 2 partes e nenhuma fratura em 4 partes. A avaliação funcional do ombro dos pacientes foi comparada usando as escalas mencionadas. Resultados: A média de escore global de UCLA foi de 23,5 pontos (8-35) e o escore de Constant-Murley 50,7 pontos sendo classificado como médio (ruim-excelente). Todas as fraturas apresentaram consolidação, 3 pacientes após um ano de pós operatório foram submetidos a retirada do material de síntese por apresentarem impacto subacromial. Conclusão: Foi observado que a escala de Constant-Murley é mais adequada para a avaliação da funcionalidade do ombro nos pacientes submetidos à osteossíntese do úmero proximal, uma vez que avaliou dor e arco de movimento de forma mais eficiente e fidedigna. </ subfield >
</ varfield >
< varfield i1 =" " i2 =" " id =" 260 " >
< subfield label =" b " > Diretoria de Saúde da Marinha </ subfield >
</ varfield >
< varfield i1 =" " i2 =" " id =" 260 " >
< subfield label =" c " > 2014-07-03 00:00:00 </ subfield >
</ varfield >
< varfield i1 =" " i2 =" " id =" 856 " >
< subfield label =" q " > application/pdf </ subfield >
</ varfield >
< varfield i1 =" 4 " i2 =" 0 " id =" 856 " >
< subfield label =" u " > https://www.portaldeperiodicos.marinha.mil.br/index.php/abmn/article/view/684 </ subfield >
</ varfield >
< varfield i1 =" 0 " i2 =" " id =" 786 " >
< subfield label =" n " > Revista Arquivos Brasileiros de Medicina Naval; v. 75 n. 1 (2014): Arquivos Brasileiros de Medicina Naval </ subfield >
</ varfield >
< varfield i1 =" " i2 =" " id =" 546 " >
< subfield label =" a " > por </ subfield >
</ varfield >
< varfield i1 =" " i2 =" " id =" 540 " >
< subfield label =" a " > ##submission.copyrightStatement## </ subfield >
</ varfield >
</ oai_marc >
<?xml version="1.0" encoding="UTF-8" ?>
< rfc1807 schemaLocation =" http://info.internet.isi.edu:80/in-notes/rfc/files/rfc1807.txt http://www.openarchives.org/OAI/1.1/rfc1807.xsd " >
< bib-version > v2 </ bib-version >
< id > https://www.portaldeperiodicos.marinha.mil.br/index.php/abmn/article/view/684 </ id >
< entry > 2021-03-31T11:47:00Z </ entry >
< organization > Revista Arquivos Brasileiros de Medicina Naval </ organization >
< organization > v. 75 n. 1 (2014): Arquivos Brasileiros de Medicina Naval; 10 </ organization >
< title > Análise comparativa da funcionalidade do ombro em pacientes submetidos à osteossíntese do úmero proximal com placa bloqueada de ângulo fixo </ title >
< author > Silva, Marina </ author >
< date > 2014-11-02 00:00:00 </ date >
< other_access > url:https://www.portaldeperiodicos.marinha.mil.br/index.php/abmn/article/view/684 </ other_access >
< language > pt </ language >
< abstract > Objetivo: Comparar as escalas de UCLA (Universidade da California- Los Angeles) - modificada e Constant-Murley, na avaliação funcional do ombro de pacientes submetidos à osteossíntese do úmero proximal com placa de angulo fixo (PHILOS). Métodos: No período entre setembro de 2007 a junho de 2011 foram selecionados 10 pacientes tratados no Hospital Naval Marcílio Dias (HNMD), sendo 20% do sexo masculino com a média de idade de 42,5 anos e 80% do sexo feminino com média de idade 60,5 anos. O acompanhamento pós operatório dos pacientes foi em 9 meses e baseado na classificação de Neer, 2 pacientes apresentaram fraturas em 3 partes, 8 em 2 partes e nenhuma fratura em 4 partes. A avaliação funcional do ombro dos pacientes foi comparada usando as escalas mencionadas. Resultados: A média de escore global de UCLA foi de 23,5 pontos (8-35) e o escore de Constant-Murley 50,7 pontos sendo classificado como médio (ruim-excelente). Todas as fraturas apresentaram consolidação, 3 pacientes após um ano de pós operatório foram submetidos a retirada do material de síntese por apresentarem impacto subacromial. Conclusão: Foi observado que a escala de Constant-Murley é mais adequada para a avaliação da funcionalidade do ombro nos pacientes submetidos à osteossíntese do úmero proximal, uma vez que avaliou dor e arco de movimento de forma mais eficiente e fidedigna. </ abstract >
</ rfc1807 >